CX9020 | Basic CPU module



Giới thiệu về máy tính nhúng Beckhoff CX9020:

The CX9020 is a compact, DIN rail-mountable Ethernet control system with 1 GHz ARM Cortex™-A8 CPU. The connection for the Beckhoff I/O systems is directly integrated into the CPU module. The unit offers automatic bus system identification (E-bus or K-bus) and independently switches in the corresponding mode. The CX9020 comprises the CPU with two microSD card slots, the internal RAM and 128 kB NOVRAM as non-volatile memory. The basic configuration also includes two switched Ethernet RJ45 interfaces, four USB 2.0 interfaces and a DVI-D interface. The RJ45 interfaces are connected to an internal switch and offer a simple option for creating a line topology without the need for additional Ethernet switches. The operating system is Microsoft Windows Embedded Compact 7. TwinCAT automation software transforms a CX9020 system into a powerful PLC and motion control system that can be operated with or without visualisation. Optionally, the unit can be ordered with a fieldbus, serial or audio interface.


The extended operating temperature range between -25 and +60 °C enables application in climatically demanding situations.


Mã đặt hàng:

  • CX9020-0100 no TwinCAT
  • CX9020-0110 Windows Embedded Compact 7, no TwinCAT
  • CX9020-0111 Windows Embedded Compact 7, TwinCAT 2 PLC runtime
  • CX9020-0112 Windows Embedded Compact 7, TwinCAT 2 NC PTP runtime
  • CX9020-0115 Windows Embedded Compact 7, TwinCAT 3 runtime (XAR)

Các tùy chọn Module và phụ kiện cho Beckhoff CX9020:

  • CX9020-U900 internal, capacitive 1-second UPS to ensure secure backup of persistent application data
  • on the microSD card
  • CX1900-0123 1 GB microSD card, instead of 512 MB microSD card
  • CX1900-0125 2 GB microSD card, instead of 512 MB microSD card
  • CX1900-0127 4 GB microSD card, instead of 512 MB microSD card
  • CX1900-0129 8 GB microSD card, instead of 512 MB microSD card
  • CX2900-0107 Device modification for CX5120, CX5130, CX5140 and CX9020 Embedded PCs according to the requirements for ATEX, IECEx and FM certification. The modification is mandatory for the usage of CX5120, CX5130, CX5140 and CX9020 in hazardous areas, Zone 2/22 respectively Class I, Div. 2.
  • CX9020-N020 audio interface, 3 x 3.5 mm jack sockets, Line In, Mic In, Line Out
  • CX9020-N030 RS232 interface, D-sub plug, 9-pin (RXD, TXD, RTS, CTS)
  • CX9020-N031 RS485 interface, D-sub socket, 9-pin, configuration as an end point, without echo, termination on
  • CX9020-N031-0001 RS485 interface, D-sub socket, 9-pin, configuration as an end point, with echo, termination on
  • CX9020-N031-0002 RS485 interface, D-sub socket, 9-pin, configuration as drop point, without echo, termination off
  • CX9020-N031-0003 RS485 interface, D-sub socket, 9-pin, configuration as drop point, with echo, termination off
  • CX9020-N031-0004 RS422 interface, D-sub socket, 9-pin, configuration as full duplex end point, termination on
  • CX9020-B110 EtherCAT slave interface, EtherCAT IN and OUT (2 x RJ45)
  • CX9020-M310 PROFIBUS master interface, D-sub socket, 9-pin
  • CX9020-B310 PROFIBUS slave interface, D-sub socket, 9-pin
  • CX9020-M510 CANopen master interface, D-sub plug, 9-pin
  • CX9020-B510 CANopen slave interface, D-sub plug, 9-pin
  • CX9020-M930 PROFINET RT, controller interface, Ethernet (2 x RJ45 switch)
  • CX9020-B930 PROFINET RT, device interface, Ethernet (2 x RJ45 switched)
  • CX9020-B950 EtherNet/IP adapter interface, Ethernet (2 x RJ45 switched)