EL3xxx | Analog input

The EL3xxx EtherCAT Terminals process analog input signals for voltage, current, temperature and other measured variables.


Các mã module ngõ vào analog của hãng Beckhoff:

EL3001, ES3001
EL3001, ES3001 | EtherCAT Terminal, 1-channel analog input, voltage, ±10 V, 12 bit, single-ended
Channels:1Signal (analog):±10 VSignal resolution (analog):12 bit

EL3002, ES3002
EL3002, ES3002 | EtherCAT Terminal, 2-channel analog input, voltage, ±10 V, 12 bit, single-ended
Channels:2Signal (analog):±10 VSignal resolution (analog):12 bit

EL3004, ES3004
EL3004, ES3004 | EtherCAT Terminal, 4-channel analog input, voltage, ±10 V, 12 bit, single-ended
Channels:4Signal (analog):±10 VSignal resolution (analog):12 bit

EL3008, ES3008
EL3008, ES3008 | EtherCAT Terminal, 8-channel analog input, voltage, ±10 V, 12 bit, single-ended
Channels:8Signal (analog):±10 VSignal resolution (analog):12 bit

EL3011, ES3011
EL3011, ES3011 | EtherCAT Terminal, 1-channel analog input, current, 0…20 mA, 12 bit, differential
Channels:1Signal (analog):0…20 mASignal resolution (analog):12 bit

EL3012, ES3012
EL3012, ES3012 | EtherCAT Terminal, 2-channel analog input, current, 0…20 mA, 12 bit, differential
Channels:2Signal (analog):0…20 mASignal resolution (analog):12 bit

EL3014, ES3014
EL3014, ES3014 | EtherCAT Terminal, 4-channel analog input, current, 0…20 mA, 12 bit, differential
Channels:4Signal (analog):0…20 mASignal resolution (analog):12 bit

EL3021, ES3021
EL3021, ES3021 | EtherCAT Terminal, 1-channel analog input, current, 4…20 mA, 12 bit, differential
Channels:1Signal (analog):4…20 mASignal resolution (analog):12 bit

EL3022, ES3022
EL3022, ES3022 | EtherCAT Terminal, 2-channel analog input, current, 4…20 mA, 12 bit, differential
Channels:2Signal (analog):4…20 mASignal resolution (analog):12 bit

EL3024, ES3024
EL3024, ES3024 | EtherCAT Terminal, 4-channel analog input, current, 4…20 mA, 12 bit, differential
Channels:4Signal (analog):4…20 mASignal resolution (analog):12 bit

EL3041, ES3041
EL3041, ES3041 | EtherCAT Terminal, 1-channel analog input, current, 0…20 mA, 12 bit, single-ended
Channels:1Signal (analog):0…20 mASignal resolution (analog):12 bit

EL3042, ES3042
EL3042, ES3042 | EtherCAT Terminal, 2-channel analog input, current, 0…20 mA, 12 bit, single-ended
Channels:2Signal (analog):0…20 mASignal resolution (analog):12 bit

EL3044, ES3044
EL3044, ES3044 | EtherCAT Terminal, 4-channel analog input, current, 0…20 mA, 12 bit, single-ended
Channels:4Signal (analog):0…20 mASignal resolution (analog):12 bit

EL3048, ES3048
EL3048, ES3048 | EtherCAT Terminal, 8-channel analog input, current, 0…20 mA, 12 bit, single-ended
Channels:8Signal (analog):0…20 mASignal resolution (analog):12 bit

EL3051, ES3051
EL3051, ES3051 | EtherCAT Terminal, 1-channel analog input, current, 4…20 mA, 12 bit, single-ended
Channels:1Signal (analog):4…20 mASignal resolution (analog):12 bit

EL3052, ES3052
EL3052, ES3052 | EtherCAT Terminal, 2-channel analog input, current, 4…20 mA, 12 bit, single-ended
Channels:2Signal (analog):4…20 mASignal resolution (analog):12 bit

EL3054, ES3054 | EtherCAT Terminal, 4-channel analog input, current, 4…20 mA, 12 bit, single-ended
Channels:4Signal (analog):4…20 mASignal resolution (analog):12 bit

EL3058, ES3058
EL3058, ES3058 | EtherCAT Terminal, 8-channel analog input, current, 4…20 mA, 12 bit, single-ended
Channels:8Signal (analog):4…20 mASignal resolution (analog):12 bit

EL3061, ES3061
EL3061, ES3061 | EtherCAT Terminal, 1-channel analog input, voltage, 0…10 V, 12 bit, single-ended
Channels:1Signal (analog):0…10 VSignal resolution (analog):12 bit

EL3062, ES3062
EL3062, ES3062 | EtherCAT Terminal, 2-channel analog input, voltage, 0…10 V, 12 bit, single-ended
Channels:2Signal (analog):0…10 VSignal resolution (analog):12 bit

EL3062-0030
EL3062-0030 | EtherCAT Terminal, 2-channel analog input, voltage, 0…30 V, 12 bit, single-ended
Channels:2Signal (analog):0…30 VSignal resolution (analog):12 bit

EL3064, ES3064
EL3064, ES3064 | EtherCAT Terminal, 4-channel analog input, voltage, 0…10 V, 12 bit, single-ended
Channels:4Signal (analog):0…10 VSignal resolution (analog):12 bit

EL3068, ES3068
EL3068, ES3068 | EtherCAT Terminal, 8-channel analog input, voltage, 0…10 V, 12 bit, single-ended
Channels:8Signal (analog):0…10 VSignal resolution (analog):12 bit

EL3072
EL3072 | EtherCAT Terminal, 2-channel analog input, multi-function, ±10 V, ±20 mA, 12 bit
Channels:2Signal (analog):±10 VSignal resolution (analog):12 bit

EL3074
EL3074 | EtherCAT Terminal, 4-channel analog input, multi-function, ±10 V, ±20 mA, 12 bit
Channels:4Signal (analog):±10 VSignal resolution (analog):12 bit

EL3101, ES3101
EL3101, ES3101 | EtherCAT Terminal, 1-channel analog input, voltage, ±10 V, 16 bit, differential
Channels:1Signal (analog):±10 VSignal resolution (analog):16 bit

EL3102, ES3102
EL3102, ES3102 | EtherCAT Terminal, 2-channel analog input, voltage, ±10 V, 16 bit, differential
Channels:2Signal (analog):±10 VSignal resolution (analog):16 bit

EL3104, ES3104
EL3104, ES3104 | EtherCAT Terminal, 4-channel analog input, voltage, ±10 V, 16 bit, differential
Channels:4Signal (analog):±10 VSignal resolution (analog):16 bit

EL3111, ES3111
EL3111, ES3111 | EtherCAT Terminal, 1-channel analog input, current, 0…20 mA, 16 bit, differential
Channels:1Signal (analog):0…20 mASignal resolution (analog):16 bit

EL3112, ES3112
EL3112, ES3112 | EtherCAT Terminal, 2-channel analog input, current, 0…20 mA, 16 bit, differential
Channels:2Signal (analog):0…20 mASignal resolution (analog):16 bit

EL3112-0011
EL3112-0011 | EtherCAT Terminal, 2-channel analog input, current, ±20 mA, 16 bit, differential
Channels:2Signal (analog):±20 mASignal resolution (analog):16 bit

EL3114, ES3114
EL3114, ES3114 | EtherCAT Terminal, 4-channel analog input, current, 0…20 mA, 16 bit, differential
Channels:4Signal (analog):0…20 mASignal resolution (analog):16 bit

EL3121, ES3121
EL3121, ES3121 | EtherCAT Terminal, 1-channel analog input, current, 4…20 mA, 16 bit, differential
Channels:1Signal (analog):4…20 mASignal resolution (analog):16 bit

EL3122, ES3122
EL3122, ES3122 | EtherCAT Terminal, 2-channel analog input, current, 4…20 mA, 16 bit, differential
Channels:2Signal (analog):4…20 mASignal resolution (analog):16 bit

EL3124, ES3124
EL3124, ES3124 | EtherCAT Terminal, 4-channel analog input, current, 4…20 mA, 16 bit, differential
Channels:4Signal (analog):4…20 mASignal resolution (analog):16 bit

EL3124-0090
EL3124-0090 | EtherCAT Terminal, 4-channel analog input, current, 4…20 mA, 16 bit, differential, TwinSAFE SC
Channels:4Signal (analog):4…20 mASignal resolution (analog):16 bit

EL3141, ES3141
EL3141, ES3141 | EtherCAT Terminal, 1-channel analog input, current, 0…20 mA, 16 bit, single-ended
Channels:1Signal (analog):0…20 mASignal resolution (analog):16 bit

EL3142, ES3142
EL3142, ES3142 | EtherCAT Terminal, 2-channel analog input, current, 0…20 mA, 16 bit, single-ended
Channels:2Signal (analog):0…20 mASignal resolution (analog):16 bit

EL3142-0010
EL3142-0010 | EtherCAT Terminal, 2-channel analog input, current, ±10 mA, 16 bit, single-ended
Channels:2Signal (analog):±10 mASignal resolution (analog):16 bit

EL3144, ES3144
EL3144, ES3144 | EtherCAT Terminal, 4-channel analog input, current, 0…20 mA, 16 bit, single-ended
Channels:4Signal (analog):0…20 mASignal resolution (analog):16 bit

EL3151, ES3151
EL3151, ES3151 | EtherCAT Terminal, 1-channel analog input, current, 4…20 mA, 16 bit, single-ended
Channels:1Signal (analog):4…20 mASignal resolution (analog):16 bit

EL3152, ES3152
EL3152, ES3152 | EtherCAT Terminal, 2-channel analog input, current, 4…20 mA, 16 bit, single-ended
Channels:2Signal (analog):4…20 mASignal resolution (analog):16 bit

EL3154, ES3154
EL3154, ES3154 | EtherCAT Terminal, 4-channel analog input, current, 4…20 mA, 16 bit, single-ended
Channels:4Signal (analog):4…20 mASignal resolution (analog):16 bit

EL3161, ES3161
EL3161, ES3161 | EtherCAT Terminal, 1-channel analog input, voltage, 0…10 V, 16 bit, single-ended
Channels:1Signal (analog):0…10 VSignal resolution (analog):16 bit

EL3162, ES3162
EL3162, ES3162 | EtherCAT Terminal, 2-channel analog input, voltage, 0…10 V, 16 bit, single-ended
Channels:2Signal (analog):0…10 VSignal resolution (analog):16 bit

EL3164, ES3164
EL3164, ES3164 | EtherCAT Terminal, 4-channel analog input, voltage, 0…10 V, 16 bit, single-ended
Channels:4Signal (analog):0…10 VSignal resolution (analog):16 bit

EL3172
EL3172 | EtherCAT Terminal, 2-channel analog input, multi-function, ±10 V, ±20 mA, 16 bit
Channels:2Signal (analog):parameterizableSignal resolution (analog):16 bit

EL3174
EL3174 | EtherCAT Terminal, 4-channel analog input, multi-function, ±10 V, ±20 mA, 16 bit
Channels:4Signal (analog):parameterizableSignal resolution (analog):16 bit

EL3174-0002
EL3174-0002 | EtherCAT Terminal, 4-channel analog input, multi-function, ±10 V, ±20 mA, 16 bit, differential
Channels:4Signal (analog):parameterizableSignal resolution (analog):16 bit

EL3174-0030
EL3174-0030 | EtherCAT Terminal, 4-channel analog input, multi-function, ±10 V, ±20 mA, 16 bit, externally calibrated
Channels:4Signal (analog):parameterizableSignal resolution (analog):16 bitCalibration certificate (analog):externally calibrated

EL3174-0032
EL3174-0032 | EtherCAT Terminal, 4-channel analog input, multi-function, ±3 V, ±20 mA, 16 bit, differential
Channels:4Signal (analog):parameterizableSignal resolution (analog):16 bit

EL3174-0090
EL3174-0090 | EtherCAT Terminal, 4-channel analog input, multi-function, ±10 V, ±20 mA, 16 bit, TwinSAFE SC
Channels:4Signal (analog):parameterizableSignal resolution (analog):16 bit

EL3182, ES3182
EL3182, ES3182 | EtherCAT Terminal, 2-channel analog input, current, 0/4…20 mA, 16 bit, single-ended, HART
Channels:2Signal (analog):0/4…20 mASignal resolution (analog):16 bit

EL3201, ES3201
EL3201, ES3201 | EtherCAT Terminal, 1-channel analog input, temperature, RTD (Pt100), 16 bit
Channels:1Signal (analog):Resistance thermometer (RTD)Signal resolution (analog):16 bit

EL3201-0010
EL3201-0010 | EtherCAT Terminal, 1-channel analog input, temperature, RTD (Pt100), 16 bit, high-precision
Channels:1Signal (analog):Resistance thermometer (RTD)Signal resolution (analog):16 bit

EL3201-0020
EL3201-0020 | EtherCAT Terminal, 1-channel analog input, temperature, RTD (Pt100), 16 bit, high-precision, factory calibrated
Channels:1Signal (analog):Resistance thermometer (RTD)Signal resolution (analog):16 bitCalibration certificate (analog):factory calibrated

EL3201-0030
EL3201-0030 | EtherCAT Terminal, 1-channel analog input, temperature, RTD (Pt100), 16 bit, high-precision, externally calibrated
Channels:1Signal (analog):Resistance thermometer (RTD)Signal resolution (analog):16 bitCalibration certificate (analog):externally calibrated

EL3202, ES3202
EL3202, ES3202 | EtherCAT Terminal, 2-channel analog input, temperature, RTD (Pt100), 16 bit
Channels:2Signal (analog):Resistance thermometer (RTD)Signal resolution (analog):16 bit

EL3202-0010
EL3202-0010 | EtherCAT Terminal, 2-channel analog input, temperature, RTD (Pt100), 16 bit, high-precision
Channels:2Signal (analog):Resistance thermometer (RTD)Signal resolution (analog):16 bit

EL3202-0020
EL3202-0020 | EtherCAT Terminal, 2-channel analog input, temperature, RTD (Pt100), 16 bit, high-precision, factory calibrated
Channels:2Signal (analog):Resistance thermometer (RTD)Signal resolution (analog):16 bitCalibration certificate (analog):factory calibrated

EL3202-0030
EL3202-0030 | EtherCAT Terminal, 2-channel analog input, temperature, RTD (Pt100), 16 bit, high-precision, externally calibrated
Channels:2Signal (analog):Resistance thermometer (RTD)Signal resolution (analog):16 bitCalibration certificate (analog):externally calibrated

EL3204, ES3204 | EtherCAT Terminal, 4-channel analog input, temperature, RTD (Pt100), 16 bit
Channels:4Signal (analog):Resistance thermometer (RTD)Signal resolution (analog):16 bit

EL3204-0162
EL3204-0162 | EtherCAT Terminal, 4-channel analog input, multi-function, ±10 V, RTD (Pt100), 12 bit, single-ended
Channels:4Signal (analog):Resistance thermometer (RTD)Signal resolution (analog):16 bit

EL3204-0200
EL3204-0200 | EtherCAT Terminal, 4-channel analog input, temperature, RTD/NTC, 16 bit
Channels:4Signal (analog):Resistance thermometer (RTD)Signal resolution (analog):16 bit

EL3208
EL3208 | EtherCAT Terminal, 8-channel analog input, temperature, RTD (Pt100), 16 bit
Channels:8Signal (analog):Resistance thermometer (RTD)Signal resolution (analog):16 bit

EL3208-0010
EL3208-0010 | EtherCAT Terminal, 8-channel analog input, temperature, RTD (Pt1000, NTC), 16 bit
Channels:8Signal (analog):Resistance thermometer (RTD)Signal resolution (analog):16 bit

EL3214
EL3214 | EtherCAT Terminal, 4-channel analog input, temperature, RTD (Pt100), 16 bit, 3-wire connection
Channels:4Signal (analog):Resistance thermometer (RTD)Signal resolution (analog):16 bit

EL3214-0090
EL3214-0090 | EtherCAT Terminal, 4-channel analog input, temperature, RTD (Pt100), 16 bit, 3-wire connection, TwinSAFE SC
Channels:4Signal (analog):Resistance thermometer (RTD)Signal resolution (analog):16 bit

EL3218
EL3218 | EtherCAT Terminal, 8-channel analog input, temperature, RTD (Pt100), 16 bit, 3-wire connection
Channels:8Signal (analog):Resistance thermometer (RTD)Signal resolution (analog):16 bit

EL3255
EL3255 | EtherCAT Terminal, 5-channel analog input, potentiometer, 300 Ω…50 kΩ, 16 bit
Channels:5Signal (analog):PotentiometerSignal resolution (analog):16 bit

EL3311
EL3311 | EtherCAT Terminal, 1-channel analog input, temperature, thermocouple, 16 bit
Channels:1Signal (analog):Thermocouples (mV)Signal resolution (analog):16 bit

EL3312
EL3312 | EtherCAT Terminal, 2-channel analog input, temperature, thermocouple, 16 bit
Channels:2Signal (analog):Thermocouples (mV)Signal resolution (analog):16 bit

EL3314
EL3314 | EtherCAT Terminal, 4-channel analog input, temperature, thermocouple, 16 bit
Channels:4Signal (analog):Thermocouples (mV)Signal resolution (analog):16 bit

EL3314-0002
EL3314-0002 | EtherCAT Terminal, 4-channel analog input, temperature, thermocouple, 24 bit, electrically isolated
Channels:4Signal (analog):Thermocouples (mV)Signal resolution (analog):18 bit

EL3314-0010
EL3314-0010 | EtherCAT Terminal, 4-channel analog input, temperature, thermocouple, 24 bit, high-precision
Channels:4Signal (analog):Thermocouples (mV)Signal resolution (analog):18 bit

EL3314-0020
EL3314-0020 | EtherCAT Terminal, 4-channel analog input, temperature, thermocouple, 24 bit, high-precision, factory calibrated
Channels:4Signal (analog):Thermocouples (mV)Signal resolution (analog):18 bitCalibration certificate (analog):factory calibrated

EL3314-0030
EL3314-0030 | EtherCAT Terminal, 4-channel analog input, temperature, thermocouple, 24 bit, high-precision, externally calibrated
Channels:4Signal (analog):Thermocouples (mV)Signal resolution (analog):18 bitCalibration certificate (analog):externally calibrated

EL3314-0090
EL3314-0090 | EtherCAT Terminal, 4-channel analog input, temperature, thermocouple, 16 bit, TwinSAFE SC
Channels:4Signal (analog):Thermocouples (mV)Signal resolution (analog):16 bit

EL3318
EL3318 | EtherCAT Terminal, 8-channel analog input, temperature, thermocouple, 16 bit
Channels:8Signal (analog):Thermocouples (mV)Signal resolution (analog):16 bit

EL3351, ES3351
EL3351, ES3351 | EtherCAT Terminal, 1-channel analog input, measuring bridge, full bridge, 16 bit
Channels:1Signal (analog):Resistance measurementSignal resolution (analog):16 bit

EL3356, ES3356
EL3356, ES3356 | EtherCAT Terminal, 1-channel analog input, measuring bridge, full bridge, 16 bit
Channels:1Signal (analog):Resistance measurementSignal resolution (analog):16 bit

EL3356-0010
EL3356-0010 | EtherCAT Terminal, 1-channel analog input, measuring bridge, full bridge, 24 bit, high-precision
Channels:1Signal (analog):Resistance measurementSignal resolution (analog):24 bit

EL3356-0020
EL3356-0020 | EtherCAT Terminal, 1-channel analog input, measuring bridge, full bridge, 24 bit, high-precision, factory calibrated
Channels:1Signal (analog):Resistance measurementSignal resolution (analog):24 bitCalibration certificate (analog):factory calibrated

EL3356-0030
EL3356-0030 | EtherCAT Terminal, 1-channel analog input, measuring bridge, full bridge, 24 bit, high-precision, externally calibrated
Channels:1Signal (analog):Resistance measurementSignal resolution (analog):24 bitCalibration certificate (analog):externally calibrated

EL3356-0090
EL3356-0090 | EtherCAT Terminal, 1-channel analog input, measuring bridge, full bridge, 24 bit, high-precision, TwinSAFE SC
Channels:1Signal (analog):Resistance measurementSignal resolution (analog):24 bit

EL3403, ES3403
EL3403, ES3403 | EtherCAT Terminal, 3-channel analog input, power measurement, 500 V AC, 1 A, 16 bit
Channels:3Signal (analog):Power measurementSignal resolution (analog):16 bit

EL3403-0010
EL3403-0010 | EtherCAT Terminal, 3-channel analog input, power measurement, 500 V AC, 5 A, 16 bit
Channels:3Signal (analog):Power measurementSignal resolution (analog):16 bit

EL3413
EL3413 | EtherCAT Terminal, 3-channel analog input, power measurement, 690 V AC, 1/5 A, 16 bit, electrically isolated
Channels:3Signal (analog):Power measurementSignal resolution (analog):16 bit

EL3423
EL3423 | EtherCAT Terminal, 3-channel analog input, power measurement, 480 V AC/DC, 1 A, 24 bit
Channels:3Signal (analog):Power measurementSignal resolution (analog):24 bit

EL3433
EL3433 | EtherCAT Terminal, 3-channel analog input, power measurement, 500 V AC, 10 A, 16 bit
Channels:3Signal (analog):Power measurementSignal resolution (analog):16 bit

EL3443
EL3443 | EtherCAT Terminal, 3-channel analog input, power measurement, 480 V AC/DC, 1 A, 24 bit
Channels:3Signal (analog):Power measurementSignal resolution (analog):24 bit

EL3443-0010
EL3443-0010 | EtherCAT Terminal, 3-channel analog input, power measurement, 480 V AC/DC, 5 A, 24 bit
Channels:3Signal (analog):Power measurementSignal resolution (analog):24 bit

EL3443-0011
EL3443-0011 | EtherCAT Terminal, 3-channel analog input, power measurement, 480 V AC/DC, 0.1 A, 24 bit
Channels:3Signal (analog):Power measurementSignal resolution (analog):24 bit

EL3443-0013
EL3443-0013 | EtherCAT Terminal, 3-channel analog input, power measurement, 480 V AC/DC, 333 mV, 24 bit
Channels:3Signal (analog):Power measurementSignal resolution (analog):24 bit

EL3443-0020
EL3443-0020 | EtherCAT Terminal, 3-channel analog input, power measurement, 480 V AC/DC, 1 A, 24 bit, factory calibrated
Channels:3Signal (analog):Power measurementSignal resolution (analog):24 bitCalibration certificate (analog):factory calibrated

EL3444
EL3444 | EtherCAT Terminal, 4-channel analog input, current, 10 A AC/DC, 24 bit, distributed power measurement, electrically isolatedNew
Channels:4Signal (analog):Power measurementSignal resolution (analog):24 bit

EL3446
EL3446 | EtherCAT Terminal, 6-channel analog input, current, 1 A, 24 bit, distributed power measurement
Channels:6Signal (analog):Power measurementSignal resolution (analog):24 bit

EL3453
EL3453 | EtherCAT Terminal, 3-channel analog input, power measurement, 690 V AC, 0.1/1/5 A, 24 bit, electrically isolated
Channels:3Signal (analog):Power measurementSignal resolution (analog):24 bit

EL3453-0020
EL3453-0020 | EtherCAT Terminal, 3-channel analog input, power measurement, 690 V AC, 0.1/1/5 A, 24 bit, electrically isolated, factory calibrated
Channels:3Signal (analog):Power measurementSignal resolution (analog):24 bitCalibration certificate (analog):factory calibrated

EL3453-0100
EL3453-0100 | EtherCAT Terminal, 3-channel analog input, power measurement, 130 V AC, 0.1/1/5 A, 24 bit, electrically isolated
Channels:3Signal (analog):Power measurementSignal resolution (analog):24 bit

EL3483
EL3483 | EtherCAT Terminal, 3-channel analog input, mains monitor, 480 V AC, 24 bit
Channels:3Signal (analog):Power measurementSignal resolution (analog):24 bit

EL3483-0060
EL3483-0060 | EtherCAT Terminal, 3-channel analog input, mains monitor, 480 V AC, 24 bit, with analog values
Channels:3Signal (analog):Power measurementSignal resolution (analog):24 bit

EL3602, ES3602
EL3602, ES3602 | EtherCAT Terminal, 2-channel analog input, voltage, ±10 V, ±5 V, ±2.5 V, ±1.25 V, 24 bit, high-precision
Channels:2Signal (analog):±10 VSignal resolution (analog):24 bit

EL3602-0002
EL3602-0002 | EtherCAT Terminal, 2-channel analog input, voltage, ±200 mV, 24 bit, high-precision
Channels:2Signal (analog):±200 mVSignal resolution (analog):24 bit

EL3602-0010
EL3602-0010 | EtherCAT Terminal, 2-channel analog input, voltage, ±75 mV, 24 bit, high-precision
Channels:2Signal (analog):±75 mASignal resolution (analog):24 bit

EL3602-0020
EL3602-0020 | EtherCAT Terminal, 2-channel analog input, voltage, ±10 V, ±5 V, ±2.5 V, ±1.25 V, 24 bit, high-precision, factory calibrated
Channels:2Signal (analog):±10 VSignal resolution (analog):24 bitCalibration certificate (analog):factory calibrated

EL3612, ES3612
EL3612, ES3612 | EtherCAT Terminal, 2-channel analog input, current, 0…20 mA, 24 bit, high-precision
Channels:2Signal (analog):0…20 mASignal resolution (analog):24 bit

EL3612-0020
EL3612-0020 | EtherCAT Terminal, 2-channel analog input, current, 0…20 mA, 24 bit, high-precision, factory calibrated
Channels:2Signal (analog):0…20 mASignal resolution (analog):24 bitCalibration certificate (analog):factory calibrated

EL3621-0020
EL3621-0020 | EtherCAT Terminal, 1-channel analog input, current, 4…20 mA, 24 bit, high-precision, factory calibrated
Channels:1Signal (analog):4…20 mASignal resolution (analog):24 bitCalibration certificate (analog):factory calibrated

EL3632
EL3632 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer, 16 bit, 50 ksps
Channels:2Signal (analog):IEPE interfaceSignal resolution (analog):16 bit

EL3632-0020
EL3632-0020 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer, 16 bit, 50 ksps, factory calibrated
Channels:2Signal (analog):IEPE interfaceSignal resolution (analog):16 bitCalibration certificate (analog):factory calibrated

EL3681, ES3681
EL3681, ES3681 | EtherCAT Terminal, 1-channel analog input, multimeter, 300 V AC/DC, 10 A, 19 bit
Channels:1Signal (analog):Oscilloscope/multimeterSignal resolution (analog):18 bit

EL3681-0020
EL3681-0020 | EtherCAT Terminal, 1-channel analog input, multimeter, 300 V AC/DC, 10 A, 19 bit, factory calibrated
Channels:1Signal (analog):Oscilloscope/multimeterSignal resolution (analog):18 bitCalibration certificate (analog):factory calibrated

EL3681-0030
EL3681-0030 | EtherCAT Terminal, 1-channel analog input, multimeter, 300 V AC/DC, 10 A, 19 bit, externally calibrated
Channels:1Signal (analog):Oscilloscope/multimeterSignal resolution (analog):18 bitCalibration certificate (analog):externally calibrated

EL3692
EL3692 | EtherCAT Terminal, 2-channel analog input, resistance, 100 mΩ…10 MΩ, 24 bit
Channels:2Signal (analog):Resistance measurementSignal resolution (analog):24 bit

EL3692-0020
EL3692-0020 | EtherCAT Terminal, 2-channel analog input, resistance, 100 mΩ…10 MΩ, 24 bit, factory calibrated
Channels:2Signal (analog):Resistance measurementSignal resolution (analog):24 bitCalibration certificate (analog):factory calibrated

EL3692-0030
EL3692-0030 | EtherCAT Terminal, 2-channel analog input, resistance, 100 mΩ…10 MΩ, 24 bit, externally calibrated
Channels:2Signal (analog):Resistance measurementSignal resolution (analog):24 bitCalibration certificate (analog):externally calibrated

EL3702, ES3702
EL3702, ES3702 | EtherCAT Terminal, 2-channel analog input, voltage, ±10 V, 16 bit, oversampling
Channels:2Signal (analog):±10 VSignal resolution (analog):16 bit

EL3702-0015
EL3702-0015 | EtherCAT Terminal, 2-channel analog input, voltage, ±150 mV, 16 bit, oversampling
Channels:2Signal (analog):±150 mASignal resolution (analog):16 bit

EL3742, ES3742
EL3742, ES3742 | EtherCAT Terminal, 2-channel analog input, current, 0…20 mA, 16 bit, oversampling
Channels:2Signal (analog):0…20 mASignal resolution (analog):16 bit

EL3751
EL3751 | EtherCAT Terminal, 1-channel analog input, multi-function, 24 bit, 10 ksps
Channels:1Signal (analog):parameterizableSignal resolution (analog):24 bit

EL3751-0004
EL3751-0004 | EtherCAT Terminal, 1-channel analog input, temperature, RTD (Pt100), 24 bit, 10 ksps
Channels:1Signal (analog):parameterizableSignal resolution (analog):24 bit

EL3751-0020
EL3751-0020 | EtherCAT Terminal, 1-channel analog input, multi-function, 24 bit, 10 ksps, factory calibrated
Channels:1Signal (analog):parameterizableSignal resolution (analog):24 bitCalibration certificate (analog):factory calibrated

EL3751-0024
EL3751-0024 | EtherCAT Terminal, 1-channel analog input, temperature, RTD (Pt100), 24 bit, 10 ksps, factory calibrated
Channels:1Signal (analog):parameterizableSignal resolution (analog):24 bitCalibration certificate (analog):factory calibrated

EL3773
EL3773 | EtherCAT Terminal, 3-channel analog input, multi-function, 500 V AC/DC, 1 A, 16 bit, 10 ksps, oversampling
Channels:3Signal (analog):Power monitoringSignal resolution (analog):16 bit

EL3783
EL3783 | EtherCAT Terminal, 3-channel analog input, multi-function, 690 V AC, 1/5 A, 16 bit, 20 ksps, electrically isolated, oversampling
Channels:3Signal (analog):Power monitoringSignal resolution (analog):16 bit

EL3783-0100
EL3783-0100 | EtherCAT Terminal, 3-channel analog input, multi-function, 130 V AC, 1/5 A, 16 bit, 20 ksps, electrically isolated, oversampling
Channels:3Signal (analog):Power monitoringSignal resolution (analog):16 bit

ELM3002-0000
ELM3002-0000 | EtherCAT Terminal, 2-channel analog input, voltage, ±30 V…±20 mV, 24 bit, 20 ksps
Channels:2Type/signal:voltageSignal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3002-0030
ELM3002-0030 | EtherCAT Terminal, 2-channel analog input, voltage, ±30 V…±20 mV, 24 bit, 20 ksps, externally calibrated
Channels:2Type/signal:voltageSignal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3002-0205
ELM3002-0205 | EtherCAT Terminal, 2-channel analog input, voltage, ±60 V…±1200 V, 24 bit, 50 ksps, electrically isolated, 4 mm socketNew
Channels:2Type/signal:voltageSignal resolution (analog):24 bitConnection method (signal):4 mm laboratory plug

ELM3004-0000
ELM3004-0000 | EtherCAT Terminal, 4-channel analog input, voltage, ±30 V…±20 mV, 24 bit, 10 ksps
Channels:4Type/signal:voltageSignal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3004-0030
ELM3004-0030 | EtherCAT Terminal, 4-channel analog input, voltage, ±30 V…±20 mV, 24 bit, 10 ksps, externally calibrated
Channels:4Type/signal:voltageSignal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3102-0000
ELM3102-0000 | EtherCAT Terminal, 2-channel analog input, current, ±20 mA, 24 bit, 20 ksps
Channels:2Type/signal:NAMUR, powerSignal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3102-0100
ELM3102-0100 | EtherCAT Terminal, 2-channel analog input, multi-function, ±60 V, ±20 mA, 24 bit, 20 ksps, electrically isolatedNew
Channels:2Type/signal:NAMUR, power, voltageSignal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3104-0000
ELM3104-0000 | EtherCAT Terminal, 4-channel analog input, current, ±20 mA, 24 bit, 10 ksps
Channels:4Type/signal:NAMUR, powerSignal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3104-0020
ELM3104-0020 | EtherCAT Terminal, 4-channel analog input, current, ±20 mA, 24 bit, 10 ksps, factory calibratedNew
Channels:4Type/signal:NAMUR, powerSignal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3142-0000
ELM3142-0000 | EtherCAT Terminal, 2-channel analog input, multi-function, ±10…±1.25 V, ±20 mA, 24 bit, 1 ksps
Channels:2Type/signal:NAMUR, power, voltageSignal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3144-0000
ELM3144-0000 | EtherCAT Terminal, 4-channel analog input, multi-function, ±10…±1.25 V, ±20 mA, 24 bit, 1 ksps
Channels:4Type/signal:NAMUR, power, voltageSignal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3146-0000
ELM3146-0000 | EtherCAT Terminal, 6-channel analog input, multi-function, ±10…±1.25 V, ±20 mA, 24 bit, 1 ksps
Channels:6Type/signal:NAMUR, power, voltageSignal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3148-0000
ELM3148-0000 | EtherCAT Terminal, 8-channel analog input, multi-function, ±10…±1.25 V, ±20 mA, 24 bit, 1 ksps
Channels:8Type/signal:NAMUR, power, voltageSignal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3244-0000
ELM3244-0000 | EtherCAT Terminal, 4-channel analog input, temperature, RTD, 24 bit, high-precision, 1 kspsNew
Channels:4Type/signal:temperature (RTD, TC), resistance, potentiometerSignal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3246-0000
ELM3246-0000 | EtherCAT Terminal, 6-channel analog input, temperature, RTD, 24 bit, high-precision, 1 kspsNew
Channels:6Type/signal:temperature (RTD, TC), resistance, potentiometerSignal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3344-0000
ELM3344-0000 | EtherCAT Terminal, 4-channel analog input, temperature, thermocouple, 24 bit, high-precision, 1 ksps
Channels:4Type/signal:voltage, temperature (RTD, TC)Signal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3344-0003
ELM3344-0003 | EtherCAT Terminal, 4-channel analog input, temperature, thermocouple, 24 bit, high-precision, 1 ksps, Mini-TC universal
Channels:4Type/signal:voltage, temperature (RTD, TC)Signal resolution (analog):24 bitConnection method (signal):Mini thermocouple

ELM3348-0000
ELM3348-0000 | EtherCAT Terminal, 8-channel analog input, temperature, thermocouple, 24 bit, high-precision, 1 ksps
Channels:8Type/signal:voltage, temperature (RTD, TC)Signal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3348-0003
ELM3348-0003 | EtherCAT Terminal, 8-channel analog input, temperature, thermocouple, 24 bit, high-precision, 1 ksps, Mini-TC universal
Channels:8Type/signal:voltage, temperature (RTD, TC)Signal resolution (analog):24 bitConnection method (signal):Mini thermocouple

ELM3502-0000
ELM3502-0000 | EtherCAT Terminal, 2-channel analog input, measuring bridge, full/half/quarter bridge, 24 bit, 20 ksps
Channels:2Type/signal:measuring bridge (strain gauge), potentiometer, voltage, temperature (RTD, TC)Signal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3502-0030
ELM3502-0030 | EtherCAT Terminal, 2-channel analog input, measuring bridge, full/half/quarter bridge, 24 bit, 20 ksps, externally calibrated
Channels:2Type/signal:measuring bridge (strain gauge), potentiometer, voltage, temperature (RTD, TC)Signal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3504-0000
ELM3504-0000 | EtherCAT Terminal, 4-channel analog input, measuring bridge, full/half/quarter bridge, 24 bit, 10 ksps
Channels:4Type/signal:measuring bridge (strain gauge), potentiometer, voltage, temperature (RTD, TC)Signal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3504-0030
ELM3504-0030 | EtherCAT Terminal, 4-channel analog input, measuring bridge, full/half/quarter bridge, 24 bit, 10 ksps, externally calibrated
Channels:4Type/signal:measuring bridge (strain gauge), potentiometer, voltage, temperature (RTD, TC)Signal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3542-0000
ELM3542-0000 | EtherCAT Terminal, 2-channel analog input, measuring bridge, full/half/quarter bridge, 24 bit, 1 ksps, TEDS
Channels:2Type/signal:measuring bridge (strain gauge), potentiometer, voltage, temperature (RTD, TC)Signal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3544-0000
ELM3544-0000 | EtherCAT Terminal, 4-channel analog input, measuring bridge, full/half/quarter bridge, 24 bit, 1 ksps
Channels:4Type/signal:measuring bridge (strain gauge), potentiometer, voltage, temperature (RTD, TC)Signal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3602-0000
ELM3602-0000 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer, 24 bit, 50 ksps
Channels:2Type/signal:voltage, acceleration (IEPE)Signal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3602-0002
ELM3602-0002 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer, 24 bit, 50 ksps, BNC
Channels:2Type/signal:voltage, acceleration (IEPE)Signal resolution (analog):24 bitConnection method (signal):BNC

ELM3604-0000
ELM3604-0000 | EtherCAT Terminal, 4-channel analog input, IEPE/accelerometer, 24 bit, 20 ksps
Channels:4Type/signal:voltage, acceleration (IEPE)Signal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3604-0002
ELM3604-0002 | EtherCAT Terminal, 4-channel analog input, IEPE/accelerometer, 24 bit, 20 ksps, BNC
Channels:4Type/signal:voltage, acceleration (IEPE)Signal resolution (analog):24 bitConnection method (signal):BNC

ELM3702-0000
ELM3702-0000 | EtherCAT Terminal, 2-channel analog input, multi-function, 24 bit, 10 ksps
Channels:2Type/signal:acceleration (IEPE), measuring bridge (strain gauge), NAMUR, potentiometer, voltage, power, temperature (RTD, TC), resistanceSignal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3702-0101
ELM3702-0101 | EtherCAT Terminal, 2-channel analog input, multi-function, 24 bit, 10 ksps, electrically isolated, LEMO
Channels:2Type/signal:acceleration (IEPE), measuring bridge (strain gauge), NAMUR, potentiometer, voltage, power, temperature (RTD, TC), resistanceSignal resolution (analog):24 bitConnection method (signal):LEMO

ELM3704-0000
ELM3704-0000 | EtherCAT Terminal, 4-channel analog input, multi-function, 24 bit, 10 ksps
Channels:4Type/signal:acceleration (IEPE), measuring bridge (strain gauge), NAMUR, potentiometer, voltage, power, temperature (RTD, TC), resistanceSignal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3704-0001
ELM3704-0001 | EtherCAT Terminal, 4-channel analog input, multi-function, 24 bit, 10 ksps, LEMO
Channels:4Type/signal:acceleration (IEPE), measuring bridge (strain gauge), NAMUR, potentiometer, voltage, power, temperature (RTD, TC), resistanceSignal resolution (analog):24 bitConnection method (signal):LEMO

ELM3704-0020
ELM3704-0020 | EtherCAT Terminal, 4-channel analog input, multi-function, 24 bit, 10 ksps, factory calibratedNew
Channels:4Type/signal:acceleration (IEPE), measuring bridge (strain gauge), NAMUR, potentiometer, voltage, power, temperature (RTD, TC), resistanceSignal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELM3704-1001
ELM3704-1001 | EtherCAT Terminal, 4-channel analog input, multi-function, 24 bit, 10 ksps, TC compensation
Channels:4Type/signal:voltage, temperature (RTD, TC)Signal resolution (analog):24 bitConnection method (signal):direct plug-in technique/push-in

ELX3152
ELX3152 | EtherCAT Terminal, 2-channel analog input, current, 0/4…20 mA, 16 bit, single-ended, Ex i
Channels:2Signal (analog):0/4…20 mASignal resolution (analog):16 bit

ELX3152-0090
ELX3152-0090 | EtherCAT Terminal, 2-channel analog input, current, 0/4…20 mA, 16 bit, single-ended, Ex i, TwinSAFE SC
Channels:2Signal (analog):0/4…20 mASignal resolution (analog):16 bitTwinSAFE SC:yes

ELX3158
ELX3158 | EtherCAT Terminal, 8-channel analog input, current, 4…20 mA, 16 bit, single-ended, Ex i
Channels:8Signal (analog):4…20 mASignal resolution (analog):16 bit

ELX3181
ELX3181 | EtherCAT Terminal, 1-channel analog input, current, 4…20 mA, 16 bit, single-ended, HART, Ex i
Channels:1Signal (analog):4…20 mASignal resolution (analog):16 bit

ELX3184
ELX3184 | EtherCAT Terminal, 4-channel analog input, current, 4…20 mA, 16 bit, single-ended, HART, Ex i
Channels:4Signal (analog):4…20 mASignal resolution (analog):16 bit

ELX3202
ELX3202 | EtherCAT Terminal, 2-channel analog input, temperature, RTD (Pt100), 16 bit, Ex i
Channels:2Signal (analog):Resistance thermometer (RTD)Signal resolution (analog):16 bit

ELX3202-0090
ELX3202-0090 | EtherCAT Terminal, 2-channel analog input, temperature, RTD (Pt100), 16 bit, Ex i, TwinSAFE SC
Channels:2Signal (analog):Resistance thermometer (RTD)Signal resolution (analog):16 bitTwinSAFE SC:yes

ELX3204
ELX3204 | EtherCAT Terminal, 4-channel analog input, temperature, RTD (Pt100), 16 bit, Ex i
Channels:4Signal (analog):Resistance thermometer (RTD)Signal resolution (analog):16 bit

ELX3204-0090
ELX3204-0090 | EtherCAT Terminal, 4-channel analog input, temperature, RTD (Pt100), 16 bit, Ex i, TwinSAFE SC
Channels:4Signal (analog):Resistance thermometer (RTD)Signal resolution (analog):16 bitTwinSAFE SC:yes

ELX3252
ELX3252 | EtherCAT Terminal, 2-channel analog input, potentiometer, 300 Ω…40 kΩ, 16 bit, Ex i
Channels:2Signal (analog):PotentiometerSignal resolution (analog):16 bit

ELX3312
ELX3312 | EtherCAT Terminal, 2-channel analog input, temperature, thermocouple, 16 bit, Ex i
Channels:2Signal (analog):Thermocouples (mV)Signal resolution (analog):16 bit

ELX3312-0090
ELX3312-0090 | EtherCAT Terminal, 2-channel analog input, temperature, thermocouple, 16 bit, Ex i, TwinSAFE SC
Channels:2Signal (analog):Thermocouples (mV)Signal resolution (analog):16 bitTwinSAFE SC:yes

ELX3314
ELX3314 | EtherCAT Terminal, 4-channel analog input, temperature, thermocouple, 16 bit, Ex i
Channels:4Signal (analog):Thermocouples (mV)Signal resolution (analog):16 bit

ELX3314-0090
ELX3314-0090 | EtherCAT Terminal, 4-channel analog input, temperature, thermocouple, 16 bit, Ex i, TwinSAFE SC
Channels:4Signal (analog):Thermocouples (mV)Signal resolution (analog):16 bitTwinSAFE SC:yes

ELX3351
ELX3351 | EtherCAT Terminal, 1-channel analog input, measuring bridge, full bridge, 24 bit, Ex i
Channels:1Signal (analog):Resistance measurementSignal resolution (analog):24 bit

ELX3351-0090
ELX3351-0090 | EtherCAT Terminal, 1-channel analog input, measuring bridge, full bridge, 24 bit, Ex i, TwinSAFE SC
Channels:1Signal (analog):Resistance measurementSignal resolution (analog):24 bitTwinSAFE SC:yes

EM3701
EM3701 | EtherCAT Terminal, 1-channel analog input, differential pressure, ±100 hPa (±100 mbar)
Channels:1Signal (analog):Pressure measurement
EM3702
EM3702 | EtherCAT Terminal, 2-channel analog input, relative pressure, 0...7500 hPa (0…+7.5 bar)
Channels:2Signal (analog):Pressure measurement

EM3712
EM3712 | EtherCAT Terminal, 2-channel analog input, relative pressure, ±1000 hPa (-1…+1 bar)
Channels:2Signal (analog):Pressure measurement




Đăng nhận xét Blogger

 