Beckhoff KL3022 | Bus Terminal, 2-channel analog input, current, 4…20 mA, 12 bit, differential




Tổng quan về Bekhoff KL3022,

The KL3022 analog input terminal handles signals in the range from 4 to 20 mA. The current is digitized to a resolution of 12 bits and is transmitted, in an electrically isolated form, to the higher-level automation device. The input channels of the Bus Terminal have differential inputs and possess a common, internal ground potential. An open lead or overload condition are detected, and the terminal status is relayed to the controller via the K-bus. The run LEDs give an indication of the data exchange with the Bus Coupler. The error LEDs indicate an overload condition and a broken wire.


Đặt hàng:
Thương hiệu: Beckhoff
Mã đặt hàng: KL3022
Chủng loại: Mô-đun ngõ vào analog ( 4-20mA)


KL3001, KS3001
KL3001, KS3001 | Bus Terminal, 1-channel analog input, voltage, ±10 V, 12 bit, differential
Signal (analog):±10 VChannels:1Signal resolution (analog):12 bit

KL3002, KS3002
KL3002, KS3002 | Bus Terminal, 2-channel analog input, voltage, ±10 V, 12 bit, differential
Signal (analog):±10 VChannels:2Signal resolution (analog):12 bit

KL3011, KS3011
KL3011, KS3011 | Bus Terminal, 1-channel analog input, current, 0…20 mA, 12 bit, differential
Signal (analog):0…20 mAChannels:1Signal resolution (analog):12 bit

KL3012, KS3012
KL3012, KS3012 | Bus Terminal, 2-channel analog input, current, 0…20 mA, 12 bit, differential
Signal (analog):0…20 mAChannels:2Signal resolution (analog):12 bit

KL3021, KS3021
KL3021, KS3021 | Bus Terminal, 1-channel analog input, current, 4…20 mA, 12 bit, differential
Signal (analog):4…20 mAChannels:1Signal resolution (analog):12 bit

KL3022, KS3022
KL3022, KS3022 | Bus Terminal, 2-channel analog input, current, 4…20 mA, 12 bit, differential
Signal (analog):4…20 mAChannels:2Signal resolution (analog):12 bit

KL3041, KS3041
KL3041, KS3041 | Bus Terminal, 1-channel analog input, current, 0…20 mA, 12 bit, single-ended
Signal (analog):0…20 mAChannels:1Signal resolution (analog):12 bit

KL3042, KS3042
KL3042, KS3042 | Bus Terminal, 2-channel analog input, current, 0…20 mA, 12 bit, single-ended
Signal (analog):0…20 mAChannels:2Signal resolution (analog):12 bit

KL3044, KS3044
KL3044, KS3044 | Bus Terminal, 4-channel analog input, current, 0…20 mA, 12 bit, single-ended
Signal (analog):0…20 mAChannels:4Signal resolution (analog):12 bit

KL3051, KS3051
KL3051, KS3051 | Bus Terminal, 1-channel analog input, current, 4…20 mA, 12 bit, single-ended
Signal (analog):4…20 mAChannels:1Signal resolution (analog):12 bit

KL3052, KS3052
KL3052, KS3052 | Bus Terminal, 2-channel analog input, current, 4…20 mA, 12 bit, single-ended
Signal (analog):4…20 mAChannels:2Signal resolution (analog):12 bit

KL3054, KS3054
KL3054, KS3054 | Bus Terminal, 4-channel analog input, current, 4…20 mA, 12 bit, single-ended
Signal (analog):4…20 mAChannels:4Signal resolution (analog):12 bit

KL3061, KS3061
KL3061, KS3061 | Bus Terminal, 1-channel analog input, voltage, 0…10 V, 12 bit, single-ended
Signal (analog):0…10 VChannels:1Signal resolution (analog):12 bit

KL3062, KS3062
KL3062, KS3062 | Bus Terminal, 2-channel analog input, voltage, 0…10 V, 12 bit, single-ended
Signal (analog):0…10 VChannels:2Signal resolution (analog):12 bit

KL3064, KS3064
KL3064, KS3064 | Bus Terminal, 4-channel analog input, voltage, 0…10 V, 12 bit, single-ended, with shield connector
Signal (analog):0…10 VChannels:4Signal resolution (analog):12 bit

KL3102, KS3102
KL3102, KS3102 | Bus Terminal, 2-channel analog input, voltage, ±10 V, 16 bit, differential
Signal (analog):±10 VChannels:2Signal resolution (analog):16 bit

KL3112, KS3112
KL3112, KS3112 | Bus Terminal, 2-channel analog input, current, 0…20 mA, 16 bit, differential
Signal (analog):0…20 mAChannels:2Signal resolution (analog):16 bit

KL3122, KS3122
KL3122, KS3122 | Bus Terminal, 2-channel analog input, current, 4…20 mA, 16 bit, differential
Signal (analog):4…20 mAChannels:2Signal resolution (analog):16 bit

KL3132, KS3132
KL3132, KS3132 | Bus Terminal, 2-channel analog input, voltage, ±10 V, 16 bit, differential, high-precision
Signal (analog):±10 VChannels:2Signal resolution (analog):16 bit

KL3142, KS3142
KL3142, KS3142 | Bus Terminal, 2-channel analog input, current, 0…20 mA, 16 bit, differential, high-precision
Signal (analog):0…20 mAChannels:2Signal resolution (analog):16 bit

KL3152, KS3152
KL3152, KS3152 | Bus Terminal, 2-channel analog input, current, 4…20 mA, 16 bit, differential, high-precision
Signal (analog):4…20 mAChannels:2Signal resolution (analog):16 bit

KL3162, KS3162
KL3162, KS3162 | Bus Terminal, 2-channel analog input, voltage, 0…10 V, 16 bit, differential, high-precision
Signal (analog):0…10 VChannels:2Signal resolution (analog):16 bit

KL3172, KS3172
KL3172, KS3172 | Bus Terminal, 2-channel analog input, voltage, 0…2 V, 16 bit, differential, high-precision
Signal (analog):0…2 VChannels:2Signal resolution (analog):16 bit

KL3182, KS3182
KL3182, KS3182 | Bus Terminal, 2-channel analog input, voltage, ±2 V, 16 bit, differential, high-precision
Signal (analog):±2 VChannels:2Signal resolution (analog):16 bit

KL3201, KS3201
KL3201, KS3201 | Bus Terminal, 1-channel analog input, temperature, RTD (Pt100), 16 bit
Signal (analog):Resistance thermometer (RTD)Channels:1Signal resolution (analog):16 bit

KL3202, KS3202
KL3202, KS3202 | Bus Terminal, 2-channel analog input, temperature, RTD (Pt100), 16 bit
Signal (analog):Resistance thermometer (RTD)Channels:2Signal resolution (analog):16 bit

KL3204, KS3204
KL3204, KS3204 | Bus Terminal, 4-channel analog input, temperature, RTD (Pt100), 16 bit
Signal (analog):Resistance thermometer (RTD)Channels:4Signal resolution (analog):16 bit

KL3204-0030
KL3204-0030 | Bus Terminal, 4-channel analog input, temperature, NTC (10 kΩ), 16 bit
Signal (analog):Resistance thermometer (RTD)Channels:4Signal resolution (analog):16 bit

KL3208-0010
KL3208-0010 | Bus Terminal, 8-channel analog input, temperature, RTD (Pt1000, NTC), 16 bit
Signal (analog):Resistance thermometer (RTD)Channels:8Signal resolution (analog):16 bit

KL3214
KL3214 | Bus Terminal, 4-channel analog input, temperature, RTD (Pt100), 16 bit, 3-wire connection
Signal (analog):Resistance thermometer (RTD)Channels:4Signal resolution (analog):16 bit

KL3222, KS3222
KL3222, KS3222 | Bus Terminal, 2-channel analog input, temperature, RTD (Pt100), 16 bit, high-precision
Signal (analog):Resistance thermometer (RTD)Channels:2Signal resolution (analog):16 bit

KL3228, KS3228
KL3228, KS3228 | Bus Terminal, 8-channel analog input, temperature, RTD (Pt1000, Ni1000), 16 bit
Signal (analog):Resistance thermometer (RTD)Channels:8Signal resolution (analog):16 bit

KL3311
KL3311 | Bus Terminal, 1-channel analog input, temperature, thermocouple, 16 bit
Signal (analog):Thermocouples (mV)Channels:1Signal resolution (analog):16 bit

KL3312
KL3312 | Bus Terminal, 2-channel analog input, temperature, thermocouple, 16 bit
Signal (analog):Thermocouples (mV)Channels:2Signal resolution (analog):16 bit

KL3314
KL3314 | Bus Terminal, 4-channel analog input, temperature, thermocouple, 16 bit
Signal (analog):Thermocouples (mV)Channels:4Signal resolution (analog):16 bit

KL3351, KS3351
KL3351, KS3351 | Bus Terminal, 1-channel analog input, measuring bridge, full bridge, 16 bit
Signal (analog):Resistance measurementChannels:1Signal resolution (analog):16 bit

KL3356, KS3356
KL3356, KS3356 | Bus Terminal, 1-channel analog input, measuring bridge, full bridge, 16 bit, high-precision
Signal (analog):Resistance measurementChannels:1Signal resolution (analog):16 bit

KL3361, KS3361
KL3361, KS3361 | Bus Terminal, 1-channel analog input, voltage, ±20 mV, 15 bit, oscilloscope function 
Signal (analog):Oscilloscope/multimeterChannels:1Signal resolution (analog):14 bit

KL3362, KS3362
KL3362, KS3362 | Bus Terminal, 2-channel analog input, voltage, ±10 V, 15 bit, oscilloscope function 
Signal (analog):Oscilloscope/multimeterChannels:2Signal resolution (analog):14 bit

KL3403, KS3403
KL3403, KS3403 | Bus Terminal, 3-channel analog input, power measurement, 500 V AC, 1 A, 16 bit
Signal (analog):Power measurementChannels:3Signal resolution (analog):16 bit

KL3404, KS3404
KL3404, KS3404 | Bus Terminal, 4-channel analog input, voltage, ±10 V, 12 bit, single-ended
Signal (analog):±10 VChannels:4Signal resolution (analog):12 bit

KL3408, KS3408
KL3408, KS3408 | Bus Terminal, 8-channel analog input, voltage, ±10 V, 12 bit, single-ended
Signal (analog):±10 VChannels:8Signal resolution (analog):12 bit

KL3444, KS3444
KL3444, KS3444 | Bus Terminal, 4-channel analog input, current, 0…20 mA, 12 bit, single-ended
Signal (analog):0…20 mAChannels:4Signal resolution (analog):12 bit

KL3448, KS3448
KL3448, KS3448 | Bus Terminal, 8-channel analog input, current, 0…20 mA, 12 bit, single-ended
Signal (analog):0…20 mAChannels:8Signal resolution (analog):12 bit

KL3453
KL3453 | Bus Terminal, 3-channel analog input, power measurement, 690 V AC, 0.1/1/5 A, 24 bit, electrically isolated
Signal (analog):Power measurementChannels:3Signal resolution (analog):24 bit

KL3454, KS3454
KL3454, KS3454 | Bus Terminal, 4-channel analog input, current, 4…20 mA, 12 bit, single-ended
Signal (analog):4…20 mAChannels:4Signal resolution (analog):12 bit

KL3458, KS3458
KL3458, KS3458 | Bus Terminal, 8-channel analog input, current, 4…20 mA, 12 bit, single-ended
Signal (analog):4…20 mAChannels:8Signal resolution (analog):12 bit

KL3464, KS3464
KL3464, KS3464 | Bus Terminal, 4-channel analog input, voltage, 0…10 V, 12 bit, single-ended
Signal (analog):0…10 VChannels:4Signal resolution (analog):12 bit

KL3468, KS3468
KL3468, KS3468 | Bus Terminal, 8-channel analog input, voltage, 0…10 V, 12 bit, single-ended
Signal (analog):0…10 VChannels:8Signal resolution (analog):12 bit

KL3681, KS3681
KL3681, KS3681 | Bus Terminal, 1-channel analog input, multimeter, 300 V AC/DC, 10 A, 19 bit
Signal (analog):Oscilloscope/multimeterChannels:1Signal resolution (analog):18 bit

KM3701
KM3701 | Bus Terminal module, 1-channel analog input, differential pressure, ±100 hPa (±100 mbar)
Signal (analog):Pressure measurementChannels:1

KM3702
KM3702 | Bus Terminal module, 2-channel analog input, relative pressure, 0...7500 hPa (0…+7.5 bar)
Signal (analog):Pressure measurementChannels:2

KM3712
KM3712 | Bus Terminal module, 2-channel analog input, relative pressure, ±1000 hPa (-1…+1 bar)
Signal (analog):Pressure measurementChannels:2

Xem thêm:
Video dùng thử Beckhoff KL3022:



Đăng nhận xét Blogger

 